Diverter or "sampling" valves with no metal parts in wetted area. Design features a non-sticking shaft with an upper and lower diaphragm separating the liquid from opposing springs, plus secondary seals with Fail Dry safety vents. Suitable for virtually all solutions. Series THP is not specifically designed for vacuum service; consult factory if needed.
Direct acting; flow is normally through an outlet port, at 90 degrees from the inlet port, on the same plane. When the valve is energized, flow is switched to an outlet port inline with the inlet port, also on the same plane.
Pressure or drain. (for vacuum applications, please call our Tech Group at 973-256-3000).
Series THP diverts flow of highly corrosive and ultra-pure liquids. Suitable for virtually all types of corrosive and ultrapure liquids. They do not require pressure to aid in opening the valve.
THP is ideal for sprayhead or filter applications where high backpressures exist.
These True Blue solenoid valves are direct acting. They have an upper and lower diaphragm separating the liquid from opposing springs. They are constructed of Geon PVC with Viton or EPDM diaphragms. External fasteners are stainless steel (no metals in wetted area).
Available in 1/4" and 1/2", the THP has a Cv rating at .31 with a 1/8" orifice, .52 with a 3/16 orifice, and .61 with a 1/4" orifice.
Valve performs to 1,000,000 cycles with EPDM diaphragms (Viton diaphragms perform to 100,000 on Series THP). After 1,000,000 cycles (100,000 for Viton), we recommend that the valve be disassembled and inspected. It is also recommended to replace the elastomer seals and u-cups at this point. Contact your distributor for a seal kit. For heavy use applications, you may wish to order a spare seal kit with the valve. Seal replacement takes but a few minutes with common tools; no special training is required.
Inlet and backpressure to 100 psi (4,8 bar) at room temperature (75 F) with smallest (1/8") orifice. Drops to 70 psi with 3/16" orifice, and 40 with 1/4" orifice.
If one of the outlets is plugged to create either a normally-closed or normally-open 2-way valve, the maximum pressure ratings are 40 psi inlet and backpressure.
A 20 watt NEMA 4X continuous duty coil is standard. When the coil is energized, the valve closes and will remain closed until the coil is de-energized. Coils are available in general purpose or explosion-proof, water tight construction. AC voltages are 24, 120, 240 and 480. DC available; please call our Tech Group at 973-256-3000. Other coils available.


**Model numbers shown with "W20" NEMA 4X coils. If explosion-proof coil is required, replace "W20" with "E20" in the part number. If general purpose coils are needed, replace with "G20". With all coils, please specify voltage.
NOTES: Maximum inlet pressure ratings are at full line voltages. Other materials are available; consult factory. The maximum pressure differential is the same as the maximum inlet pressure. 1/8" and 3/8" sizes are available in quantity purchases, or we suggest you simply use an appropriate bushing. It is possible to create either a normally-open or normally-closed 2-way valve by simply plugging the appropriate outlet. Pressure ratings in the table are at 75 degrees F (24 C). The THP is not yet represented on our CADlink page. If you need a drawing for your project, we recommend that you right-click the image above, and "save as."
Plast-O-Matic Valves, Inc.
1384 Pompton Avenue
Cedar Grove, NJ 07009-1095 USA
Voice: (973) 256-3000
Fax: (973) 256-4745
Top of Page
Kynar® is a registered trademark of Atofina., Corzan™ is a trademark of Noveon., FAIL-DRY® and TRUE BLUE® are registered trademarks of Plast-O-Matic Valves, Inc.
Copyright© 1997-2003 Plast-O-Matic Valves, Inc.
Viton® is a registered trademark of DuPont Dow Elastomers.